Smart PWM Solar Charge Current Controller - Customizable Power, Volt, and Amp
- DCK Series, Customizable: PV55~100V, 10-60A, 12/24/48Vdc
This intelligent PWM solar charging current controller uses advanced PWM technology to accurately control the charging current. JOEYOUNG’s PWM solar charge current controllers are easy to install and operate, it provides all-round protection for your solar panels and batteries. Whether it is home power generation, outdoor camping, or street light monitoring, it can be easily handled.
- High charging efficiency
- 6 load working modes
- LCD displays full working information
- Self-check function
- Multi-stage charging management
- Intelligent temperature protection
- Precise temperature compensation
- Compatible with AGM, GEL, WET, Lifepo4 and other battery types
- With LCD Display
LED fault indicators and an LCD screen which can display abnormality information help users to quickly identify system faults.
- Battery Type Selectable
Supports AGM, GEL, WET, and Lifepo4 batteries, offering flexibility for different energy storage needs.
- Parameters Settable
Allows customization of over-voltage, low voltage disconnect, and low voltage reconnect settings, ensuring optimal battery protection and system performance.
Battery Charging Parameters | |||||
---|---|---|---|---|---|
Battery Mode | B01 | B02 | B03 | B04 | B05 |
Battery Type | AGM | GEL | WET | LIFEPO4 | LIFEPO4 |
Battery Voltage | 12/24V/48V | 12/24V/48V | 12/24V/48V | 12.8V | 25.6V |
Absorption | 14.4/28.8V/57.6V | 14.2/28.4V/56.8V | 14.6/29.2V/58.4V | 14.2V | 28.4V |
Float | 13.7/27.4V/54.8V | 13.7/27.4V/54.8V | 13.7/27.4V/54.8V | 13.35V | 26.7V |
Equalize | None | None | 14.8/29.6V/59.2V | None | None |
Equalize Duration | None | None | 1time every 2 months | None | None |
Low Volt. Disconnect | 11.2/22.4V/44.8V | 11.2/22.4V/44.8V | 11.2/22.4V/44.8V | 11.2V | 22.4V |
Low Volt. Disconnect Setting Range | 10.5V-12.0V 21.0V-24.0V 42.0V-48.0V | 10.5V-12.0V 21.0V-24.0V 42.0V-48.0V | 10.5V-12.0V 21.0V-24.0V 42.0V-48.0V | 10.5V-12.0V | 21.0V-24.0V |
Low Volt. Reconnect | 12.6/25.2V/50.4V | 12.6/25.2V/50.4V | 12.6/25.2V/50.4V | 12.6 | 25.2V |
Low Volt. Reconnect Setting Range | 12.0V-13.5V 24.0V-27.0V 48.0V-54.0V | 12.0V-13.5V 24.0V-27.0V 48.0V-54.0V | 12.0V-13.5V 24.0V-27.0V 48.0V-54.0V | 12.0V-13.5V | 24.0V-27.0V |
Battery Charging Parameters | |||
---|---|---|---|
Battery Mode | B01 | B02 | B03 |
Battery Type | AGM | GEL | WET |
Battery Voltage | 12/24V/48V | 12/24V/48V | 12/24V/48V |
Absorption | 14.4/28.8V/57.6V | 14.2/28.4V/56.8V | 14.6/29.2V/58.4V |
Float | 13.7/27.4V/54.8V | 13.7/27.4V/54.8V | 13.7/27.4V/54.8V |
Equalize | None | None | 14.8/29.6V/59.2V |
Equalize Duration | None | None | 1time every 2 months |
Low Volt. Disconnect | 11.2/22.4V/44.8V | 11.2/22.4V/44.8V | 11.2/22.4V/44.8V |
Low Volt. Disconnect Setting Range | 10.5V-12.0V 21.0V-24.0V 42.0V-48.0V | 10.5V-12.0V 21.0V-24.0V 42.0V-48.0V | 10.5V-12.0V 21.0V-24.0V 42.0V-48.0V |
Low Volt. Reconnect | 12.6/25.2V/50.4V | 12.6/25.2V/50.4V | 12.6/25.2V/50.4V |
ow Volt. Reconnect Setting Range | 12.0V-13.5V 24.0V-27.0V 48.0V-54.0V | 12.0V-13.5V 24.0V-27.0V 48.0V-54.0V | 12.0V-13.5V 24.0V-27.0V 48.0V-54.0V |
Model | DCK1210 | DCK1220 | DCK1230 |
---|---|---|---|
Battery Voltage | 12V/24V Auto Select | 12V/24V Auto Select | 12V/24V Auto Select |
Charge & Load Current | 10A | 20A | 30A |
Charge mode | PWM, Time and Lighting Control | PWM, Time and Lighting Control | PWM, Time and Lighting Control |
Maximum solar voltage | 55V | 55V | 55V |
Maximum output power | 120W/240W | 240W/480W | 360W/720W |
Protections | Reverse polarity connection of the solar panels; Reverse polarity connection of the battery; Over-charge ; Over-discharge; Over-load ; Over-temperature; Short-circuit | ||
Overload Protection | shut down after 60s in case of 110%-130% load, shut down after 5s in case of 130%-160% load, Short circuit: immediate shut | ||
Temperature Protection | 1. When temp up to 85℃, the controller will enter into the first protection phase: it will lower the PV input current in order to lower the temp. There is no alarm on the LCD display. 2. When temp >90℃, the controller will enter into the second protection phase: the PV input current will be reduced to zero,the load output will be switched off and a high temp alarm icon will show on the LCD. 3. After the temp has decreased to less than 82℃, Blue Solar PWM | ||
Self consumption | <10mA | <10mA | <10mA |
USB | 5V 2A (total from 2 USB outputs) | 5V 2A (total from 2 USB outputs) | 5V 2A (total from 2 USB outputs) |
Terminal Size | 6mm² / AWG10 | 6mm² / AWG10 | 6mm² / AWG10 |
Mounting | Vertical wall mount, indoor only | Vertical wall mount, indoor only | Vertical wall mount, indoor only |
Humidity non condensing | Max. 95% | Max. 95% | Max. 95% |
Cooling | Natural convection | Natural convection | Natural convection |
Protection class | IP20 | IP20 | IP20 |
Operating temperature | -20°C to +50°C (full load) | -20°C to +50°C (full load) | -20°C to +50°C (full load) |
Humidity range | ≤95% (N.C.) | ≤95% (N.C.) | ≤95% (N.C.) |
Dimension | 150*85*35mm | 150*85*35mm | 150*85*35mm |
Weight | 230g | 230g | 230g |
Model | DCK4820 | DCK4830 | |
---|---|---|---|
Battery Voltage | 48V | 48V | |
Charge & Load Current | 20A | 30A | |
Charge mode | PWM, Time and Lighting Control | PWM, Time and Lighting Control | |
Maximum solar voltage | 100V | 100V | |
Maximum output power | 960W | 1440W | |
Protections | Reverse polarity connection of the solar panels; Reverse polarity connection of the battery; Over-charge ; Over-discharge; Over-load ; Over-temperature; Short-circuit | ||
Overload Protection | shut down after 60s in case of 110%-130% load, shut down after 5s in case of 130%-160% load, Short circuit: immediate shut | ||
Temperature Protection | 1. When temp up to 85℃, the controller will enter into the first protection phase: it will lower the PV input current in order to lower the temp. There is no alarm on the LCD display. 2. When temp >90℃, the controller will enter into the second protection phase: the PV input current will be reduced to zero,the load output will be switched off and a high temp alarm icon will show on the LCD. 3. After the temp has decreased to less than 82℃, Blue Solar PWM | ||
Self consumption | <10mA | <10mA | |
USB | 5V 2A (total from 2 USB outputs) | 5V 2A (total from 2 USB outputs) | |
Terminal Size | 6mm² / AWG10 | 6mm² / AWG10 | |
Mounting | Vertical wall mount, indoor only | Vertical wall mount, indoor only | |
Humidity non condensing | Max. 95% | Max. 95% | |
Cooling | Natural convection | Natural convection | |
Protection class | IP20 | IP20 | |
Operating temperature | -20°C to +50°C (full load) | -20°C to +50°C (full load) | |
Humidity range | ≤95% (N.C.) | ≤95% (N.C.) | |
Dimension | 150*85*35mm | 150*85*35mm | |
Weight | 230g | 230g |
Model | DCK1240 | DCK1250 | DCK1260 |
---|---|---|---|
Battery Voltage | 12V/24V Auto Select | 12V/24V Auto Select | 12V/24V Auto Select |
Charge & Load Current | 40A | 50A | 60A |
Charge mode | PWM, Time and Lighting Control | PWM, Time and Lighting Control | PWM, Time and Lighting Control |
Maximum solar voltage | 47V | 47V | 47V |
Maximum output power | 480W/960W | 600W/1200W | 720W/1440W |
Protections | Reverse polarity connection of the solar panels; Reverse polarity connection of the battery; Over-charge ; Over-discharge; Over-load ; Over-temperature; Short-circuit | ||
Overload Protection | shut down after 60s in case of 110%-130% load, shut down after 5s in case of 130%-160% load, Short circuit: immediate shut | ||
Temperature Protection | 1. When temp up to 85℃, the controller will enter into the first protection phase: it will lower the PV input current in order to lower the temp. There is no alarm on the LCD display. 2. When temp >90℃, the controller will enter into the second protection phase: the PV input current will be reduced to zero,the load output will be switched off and a high temp alarm icon will show on the LCD. 3. After the temp has decreased to less than 82℃, controller will be back to normal working | ||
Self consumption | <15mA | <15mA | <15mA |
USB | 5V 1A | 5V 1A | 5V 1A |
Temp compensation | Yes | Yes | Yes |
Operating temperature | -20°C to +50°C (full load) | -20°C to +50°C (full load) | -20°C to +50°C (full load) |
Humidity range | ≤95% (N.C.) | ≤95% (N.C.) | ≤95% (N.C.) |
Dimension | 220*126*63mm | 220*126*63mm | 220*126*63mm |
Weight | 1kg | 1kg | 1kg |
Model | DCK4840 | DCK4850 | DCK4860 |
---|---|---|---|
Battery Voltage | 48V | 48V | 48V |
Charge & Load Current | 40A | 50A | 60A |
Charge mode | PWM, Time and Lighting Control | PWM, Time and Lighting Control | PWM, Time and Lighting Control |
Maximum solar voltage | 100V | 100V | 100V |
Maximum output power | 1920W | 2400W | 2880W |
Protections | Reverse polarity connection of the solar panels; Reverse polarity connection of the battery; Over-charge ; Over-discharge; Over-load ; Over-temperature; Short-circuit | ||
Overload Protection | shut down after 60s in case of 110%-130% load, shut down after 5s in case of 130%-160% load, Short circuit: immediate shut | ||
Temperature Protection | 1. When temp up to 85℃, the controller will enter into the first protection phase: it will lower the PV input current in order to lower the temp. There is no alarm on the LCD display. 2. When temp >90℃, the controller will enter into the second protection phase: the PV input current will be reduced to zero,the load output will be switched off and a high temp alarm icon will show on the LCD. 3. After the temp has decreased to less than 82℃, controller will be back to normal working | ||
Self consumption | <15mA | <15mA | <15mA |
USB | 5V 1A | 5V 1A | 5V 1A |
Temp compensation | Yes | Yes | Yes |
Operating temperature | -20°C to +50°C (full load) | -20°C to +50°C (full load) | -20°C to +50°C (full load) |
Humidity range | ≤95% (N.C.) | ≤95% (N.C.) | ≤95% (N.C.) |
Dimension | 220*126*63mm | 220*126*63mm | 220*126*63mm |
Weight | 1kg | 1kg | 1kg |
Generally includes demand communication, solution design, production and manufacturing, testing and inspection, delivery and other links. The specific process may vary from manufacturer to manufacturer.
The operating voltage range of different models and customized controllers may be different. The common ones are 12V, 24V, 48V, etc., which can be determined according to the customized requirements.
When installing, pay attention to choosing a suitable installation location to avoid direct sunlight, rain and high temperature environment; ensure that the connection line is correct and firm to avoid short circuit and poor contact; strictly follow the product manual for installation operations.