Smart PWM Solar Charge Current Controller - Customizable Power, Volt, and Amp

This intelligent PWM solar charging current controller uses advanced PWM technology to accurately control the charging current. JOEYOUNG’s PWM solar charge current controllers are easy to install and operate, it provides all-round protection for your solar panels and batteries. Whether it is home power generation, outdoor camping, or street light monitoring, it can be easily handled.

  • High charging efficiency
  • 6 load working modes
  • LCD displays full working information
  • Self-check function
  • Multi-stage charging management
  • Intelligent temperature protection
  • Precise temperature compensation
  • Compatible with AGM, GEL, WET, Lifepo4 and other battery types
With LCD Display

LED fault indicators and an LCD screen which can display abnormality information help users to quickly identify system faults.

Supports AGM, GEL, WET, and Lifepo4 batteries, offering flexibility for different energy storage needs.

Up to 6 units in parallel for capacity extension

Allows customization of over-voltage, low voltage disconnect, and low voltage reconnect settings, ensuring optimal battery protection and system performance.

Battery Charging Parameters
Battery Mode B01 B02 B03 B04 B05
Battery Type AGM GEL WET LIFEPO4 LIFEPO4
Battery Voltage 12/24V/48V 12/24V/48V 12/24V/48V 12.8V 25.6V
Absorption 14.4/28.8V/57.6V 14.2/28.4V/56.8V 14.6/29.2V/58.4V 14.2V 28.4V
Float 13.7/27.4V/54.8V 13.7/27.4V/54.8V 13.7/27.4V/54.8V 13.35V 26.7V
Equalize None None 14.8/29.6V/59.2V None None
Equalize Duration None None 1time every 2 months None None
Low Volt. Disconnect 11.2/22.4V/44.8V 11.2/22.4V/44.8V 11.2/22.4V/44.8V 11.2V 22.4V
Low Volt. Disconnect Setting Range 10.5V-12.0V 21.0V-24.0V 42.0V-48.0V 10.5V-12.0V 21.0V-24.0V 42.0V-48.0V 10.5V-12.0V 21.0V-24.0V 42.0V-48.0V 10.5V-12.0V 21.0V-24.0V
Low Volt. Reconnect 12.6/25.2V/50.4V 12.6/25.2V/50.4V 12.6/25.2V/50.4V 12.6 25.2V
Low Volt. Reconnect Setting Range 12.0V-13.5V 24.0V-27.0V 48.0V-54.0V 12.0V-13.5V 24.0V-27.0V 48.0V-54.0V 12.0V-13.5V 24.0V-27.0V 48.0V-54.0V 12.0V-13.5V 24.0V-27.0V
Battery Charging Parameters
Battery Mode B01 B02 B03
Battery Type AGM GEL WET
Battery Voltage 12/24V/48V 12/24V/48V 12/24V/48V
Absorption 14.4/28.8V/57.6V 14.2/28.4V/56.8V 14.6/29.2V/58.4V
Float 13.7/27.4V/54.8V 13.7/27.4V/54.8V 13.7/27.4V/54.8V
Equalize None None 14.8/29.6V/59.2V
Equalize Duration None None 1time every 2 months
Low Volt. Disconnect 11.2/22.4V/44.8V 11.2/22.4V/44.8V 11.2/22.4V/44.8V
Low Volt. Disconnect Setting Range 10.5V-12.0V
21.0V-24.0V
42.0V-48.0V
10.5V-12.0V
21.0V-24.0V
42.0V-48.0V
10.5V-12.0V
21.0V-24.0V
42.0V-48.0V
Low Volt. Reconnect 12.6/25.2V/50.4V 12.6/25.2V/50.4V 12.6/25.2V/50.4V
ow Volt. Reconnect Setting Range 12.0V-13.5V
24.0V-27.0V
48.0V-54.0V
12.0V-13.5V
24.0V-27.0V
48.0V-54.0V
12.0V-13.5V
24.0V-27.0V
48.0V-54.0V
Model DCK1210 DCK1220 DCK1230
Battery Voltage 12V/24V Auto Select 12V/24V Auto Select 12V/24V Auto Select
Charge & Load Current 10A 20A 30A
Charge mode PWM, Time and Lighting Control PWM, Time and Lighting Control PWM, Time and Lighting Control
Maximum solar voltage 55V 55V 55V
Maximum output power 120W/240W 240W/480W 360W/720W
Protections Reverse polarity connection of the solar panels; Reverse polarity connection of the battery; Over-charge ; Over-discharge; Over-load ; Over-temperature; Short-circuit
Overload Protection shut down after 60s in case of 110%-130% load, shut down after 5s in case of 130%-160% load, Short circuit: immediate shut
Temperature Protection 1. When temp up to 85℃, the controller will enter into the first protection phase: it will lower the PV input current in order to lower the temp. There is no alarm on the LCD display.
2. When temp >90℃, the controller will enter into the second protection phase: the PV input current will be reduced to zero,the load output will be switched off and a high temp alarm icon will show on the LCD.
3. After the temp has decreased to less than 82℃, Blue Solar PWM
Self consumption <10mA <10mA <10mA
USB 5V 2A  (total from 2 USB outputs) 5V 2A  (total from 2 USB outputs) 5V 2A  (total from 2 USB outputs)
Terminal Size 6mm² / AWG10 6mm² / AWG10 6mm² / AWG10
Mounting Vertical wall mount, indoor only Vertical wall mount, indoor only Vertical wall mount, indoor only
Humidity non condensing Max. 95% Max. 95% Max. 95%
Cooling Natural convection Natural convection Natural convection
Protection class IP20 IP20 IP20
Operating temperature -20°C to +50°C (full load) -20°C to +50°C (full load) -20°C to +50°C (full load)
Humidity range ≤95% (N.C.) ≤95% (N.C.) ≤95% (N.C.)
Dimension 150*85*35mm 150*85*35mm 150*85*35mm
Weight 230g 230g 230g
Model DCK4820 DCK4830
Battery Voltage 48V 48V
Charge & Load Current 20A 30A
Charge mode PWM, Time and Lighting Control PWM, Time and Lighting Control
Maximum solar voltage 100V 100V
Maximum output power 960W 1440W
Protections Reverse polarity connection of the solar panels; Reverse polarity connection of the battery; Over-charge ; Over-discharge; Over-load ; Over-temperature; Short-circuit
Overload Protection shut down after 60s in case of 110%-130% load, shut down after 5s in case of 130%-160% load, Short circuit: immediate shut
Temperature Protection 1. When temp up to 85℃, the controller will enter into the first protection phase: it will lower the PV input current in order to lower the temp. There is no alarm on the LCD display.
2. When temp >90℃, the controller will enter into the second protection phase: the PV input current will be reduced to zero,the load output will be switched off and a high temp alarm icon will show on the LCD.
3. After the temp has decreased to less than 82℃, Blue Solar PWM
Self consumption <10mA <10mA
USB 5V 2A  (total from 2 USB outputs) 5V 2A  (total from 2 USB outputs)
Terminal Size 6mm² / AWG10 6mm² / AWG10
Mounting Vertical wall mount, indoor only Vertical wall mount, indoor only
Humidity non condensing Max. 95% Max. 95%
Cooling Natural convection Natural convection
Protection class IP20 IP20
Operating temperature -20°C to +50°C (full load) -20°C to +50°C (full load)
Humidity range ≤95% (N.C.) ≤95% (N.C.)
Dimension 150*85*35mm 150*85*35mm
Weight 230g 230g
Model DCK1240 DCK1250 DCK1260
Battery Voltage 12V/24V Auto Select 12V/24V Auto Select 12V/24V Auto Select
Charge & Load Current 40A 50A 60A
Charge mode PWM, Time and Lighting Control PWM, Time and Lighting Control PWM, Time and Lighting Control
Maximum solar voltage 47V 47V 47V
Maximum output power 480W/960W 600W/1200W 720W/1440W
Protections Reverse polarity connection of the solar panels; Reverse polarity connection of the battery; Over-charge ; Over-discharge; Over-load ; Over-temperature; Short-circuit
Overload Protection shut down after 60s in case of 110%-130% load, shut down after 5s in case of 130%-160% load, Short circuit: immediate shut
Temperature Protection 1. When temp up to 85℃, the controller will enter into the first protection phase: it will lower the PV input current in order to lower the temp. There is no alarm on the LCD display.
2. When temp >90℃, the controller will enter into the second protection phase: the PV input current will be reduced to zero,the load output will be switched off and a high temp alarm icon will show on the LCD.
3. After the temp has decreased to less than 82℃, controller will be back to normal working
Self consumption <15mA <15mA <15mA
USB 5V 1A 5V 1A 5V 1A
Temp compensation Yes Yes Yes
Operating temperature -20°C to +50°C (full load) -20°C to +50°C (full load) -20°C to +50°C (full load)
Humidity range ≤95% (N.C.) ≤95% (N.C.) ≤95% (N.C.)
Dimension 220*126*63mm 220*126*63mm 220*126*63mm
Weight 1kg 1kg 1kg
Model DCK4840 DCK4850 DCK4860
Battery Voltage 48V 48V 48V
Charge & Load Current 40A 50A 60A
Charge mode PWM, Time and Lighting Control PWM, Time and Lighting Control PWM, Time and Lighting Control
Maximum solar voltage 100V 100V 100V
Maximum output power 1920W 2400W 2880W
Protections Reverse polarity connection of the solar panels; Reverse polarity connection of the battery; Over-charge ; Over-discharge; Over-load ; Over-temperature; Short-circuit
Overload Protection shut down after 60s in case of 110%-130% load, shut down after 5s in case of 130%-160% load, Short circuit: immediate shut
Temperature Protection 1. When temp up to 85℃, the controller will enter into the first protection phase: it will lower the PV input current in order to lower the temp. There is no alarm on the LCD display.
2. When temp >90℃, the controller will enter into the second protection phase: the PV input current will be reduced to zero,the load output will be switched off and a high temp alarm icon will show on the LCD.
3. After the temp has decreased to less than 82℃, controller will be back to normal working
Self consumption <15mA <15mA <15mA
USB 5V 1A 5V 1A 5V 1A
Temp compensation Yes Yes Yes
Operating temperature -20°C to +50°C (full load) -20°C to +50°C (full load) -20°C to +50°C (full load)
Humidity range ≤95% (N.C.) ≤95% (N.C.) ≤95% (N.C.)
Dimension 220*126*63mm 220*126*63mm 220*126*63mm
Weight 1kg 1kg 1kg

Generally includes demand communication, solution design, production and manufacturing, testing and inspection, delivery and other links. The specific process may vary from manufacturer to manufacturer.

The operating voltage range of different models and customized controllers may be different. The common ones are 12V, 24V, 48V, etc., which can be determined according to the customized requirements.

When installing, pay attention to choosing a suitable installation location to avoid direct sunlight, rain and high temperature environment; ensure that the connection line is correct and firm to avoid short circuit and poor contact; strictly follow the product manual for installation operations.

Other Products from JOEYOUNG | Leading Inverter Supplier for Solar Power Solutions

Additional Resources About Solar Inverters

What is a String Inverter_ Benefits and How It Works in Solar Systems

What is a String Inverter: Benefits and How It Works in Solar Systems

Regarding solar power utilisation, several inverter types may be an option, but what is a string inverter? Why can it be the perfect match to ...
Pros and Cons of IGBT vs. MOSFET Inverter in Power Conversion

Pros and Cons of IGBT vs. MOSFET Inverter in Power Conversion

This article will dive into the role of IGBT and MOSFET inverters, the pros and cons, and each distinct characteristic.
What Can I Run On A 2000-watt Inverter

What Can I Run On A 2000-Watt Inverter?

This article answer the question “what can I run on a 2000-Watt inverter?” and several important information.